Flex M Engineered Receiver Instruction Manual
October 2014
Page 38 of 49
7. GEN 1 RF/CPU CHANNEL DIP SWITCH SETTINGS
The channel can be set on the RF/CPU module via the Bank 2 dip switches. The following shows the dip
switch settings for each of the channels available for each RF/CPU Module option.
NOTE: See section 3.8 for instructions on how to remove the CPU/RF module from the din rail and how to
remove the PCB from the module housing.
Channel Frequency SW4 SW5 SW6 SW7 SW8
A
902.30 MHz DOWN DOWN DOWN UP DOWN
B
904.10 MHz UP DOWN DOWN UP DOWN
C
904.30 MHz DOWN UP DOWN UP DOWN
D
905.10 MHz UP UP DOWN UP DOWN
E
905.50 MHz DOWN DOWN UP UP DOWN
F
905.70 MHz UP DOWN UP UP DOWN
G
906.60 MHz DOWN UP UP UP DOWN
H
908.70 MHz UP UP UP UP DOWN
I
908.90 MHz DOWN DOWN DOWN DOWN UP
J
909.10 MHz UP DOWN DOWN DOWN UP
K
910.10 MHz DOWN UP DOWN DOWN UP
L
910.70 MHz UP UP DOWN DOWN UP
M
911.00 MHz DOWN DOWN UP DOWN UP
N
911.20 MHz UP DOWN UP DOWN UP
O
912.00 MHz DOWN UP UP DOWN UP
P
914.20 MHz UP UP UP DOWN UP
Q
914.40 MHz DOWN DOWN DOWN UP UP
R
914.60 MHz UP DOWN DOWN UP UP
S
914.80 MHz DOWN UP DOWN UP UP
T
915.80 MHz UP UP DOWN UP UP
U
917.40 MHz DOWN DOWN UP UP UP
V
923.20 MHz UP DOWN UP UP UP
W
927.00 MHz DOWN UP UP UP UP
X
927.30 MHz UP UP UP UP UP
Table 1. CHANNEL DIP SWITCH SETTINGS FOR 900MHZ PART 15 RF/CPU MODULE