4.6.1 RELAY MODULE LED OPERATION
When the Flex M system is supplying power to the Relay module, there is an LED that indicates the
power and communication status of the Relay module.
Figure 23. GEN2 Relay Module LED Placement
OK LED
o Solid indicates module communication with system is good
o 3 Blinks indicates read/write error to attached CPU module
Additionally, there are 8 LEDs labeled 1 through 8 on the Relay module. When the LED is on, this
indicates that the relay is activated.
4.7 SERIAL COMMUNICATION MODULE
This section is applicable to the following serial communication part number(s):
25-02-074-809E
The Flex M Serial Communication module allows the communication via RS-232 (2-wire only), RS-422 (4-
wire only), or RS-485 (4-wire only). Any of these interfaces can operate in full duplex, while only RS-232
supports half duplex operation. When operating in full duplex with RS-422 and RS-485, the
communication module must always be the master. The communication module can only operate as a
slave in half duplex mode.
The Serial Communication module also support CAN-BUS 2.0B.
The Serial Communications module number is set by the rotary switch located on the lower left corner of
the board.