Magnetek Flex 12RS System Manual de Instruções Página 35

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 42
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 34
Flex 4EX System Instruction Manual
December 2012
32 of 39
8
1. For best reception the location of the receiver should be visible to the operator at all time.
2. The location selected should not be exposed to high levels of electric noise. Mounting the
receiver next to an unshielded variable frequency drive may cause minor interference. Always
locate the receiver as far away from the variable frequency drive as possible.
3. Ensure the selected location has adequate space to accommodate the receiver (refer to Fig.
18 on page 31).
4. For better reception, make sure the receiver is in an upright position.
5. Drill one hole (8mm in diameter) on the control panel or location where the receiver is to be
installed (refer to Fig. 18 on page 31).
6. Make sure the bolt is tightened after installation.
7. For system wiring please refer to page 30.
6.4 SYSTEM TESTING
1. Turn on the power source to the receiver and test the MAIN relay output by pressing the red
emergency stop button and observe that it properly opens and closes the mainline disconnect
contactor.
2. Test the operation of each function to ensure it corresponds to the transmitter direction labels or
the pendant it is replacing.
3. Test the limit switches (if any) to see if they are working properly.
4. If your new remote control is replacing an existing pendant, make sure it is completely
disconnected and placed in a safe location to prevent unwanted control commands.